Thursday, August 20, 2009

Do EGT probes / sensors come with a calibration sheet or chart?

Do these EGT probes come with a calibration sheet or chart?

The EGT probes do not come with a calibration sheet or chart. They are a standard Type K thermocouple device whose output follows the NIST Type K thermocouple linearization curve. Most modern day instrumentation can read a Type K thermocouple directly. In some cases, thermocouple amplifiers are required to interface between the thermocouple & the particular measuring instrument.